SEARCH
0-9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Prev | Current Page 68 | Next

Scott Empson and Hans Roth

"CCNP ISCW Portable Command Guide"

If either is true,
you are prompted to enter
a new enable secret
password.
80 Locking Down Routers with AutoSecure
Enter the new enable password: xxxx
% Password too short ??“ must be at least 6
characters. Password configuration failed
Enter the new enable password: xxxxxxx
Confirm the enable password: xxxxxxx
Configuring AAA local authentication
Configuring Console, Aux and VTY lines for
local authentication, exec-timeout, and
transport
Securing device against Login Attacks
Configure the following parameters
Blocking Period when Login Attack detected:
300
Maximum Login failures with the device: 3
Maximum time period for crossing the failed
login attempts: 60
Prompts you to enter a
new enable password,
which must be at least six
characters
Checks for AAA local
authentication and
whether a local user
account exists. If neither is
true, you are prompted to
enter a username and
password.
Sets the blocking period,
in seconds??”known as the
quiet period
Sets the maximum number
of failed login attempts that
triggers the quiet period
Sets the duration of time
in which the allowed
number of failed login
attempts must be made
before the blocking period
is triggered
Configure SSH server? [yes]: y Con?¬?gures SSH
functionality
If you answer yes,
AutoSecure automatically
con?¬?gures the SSH
timeout to 60 seconds
and the number of SSH
authentication retries to
two.